0001029: cArcFigure angle arguments are inconsistent with the rotation transformation in the Canvas API.
Rotation transformation is correct because PI/2 rotates X into Y clockwise. As opposed to cArgFigure PI/2 angle (rotates counter-clockwise according to documentation & implementation) which results in -Y. We think that cArcFigure should be fixed (cPieSlice?).