0000126OMNeT++IDE / NED editorpublic2009-12-22 00:322010-01-04 16:20
andras 
levy 
normalminoralways
resolvedfixed 
4.0 
4.1 
0000126: "Edit parameters" dialog does not save values when opening it for a connection
Select a connection (DelayChannel or DatarateChannel) in the graphical NED editor, choose "Edit Parameters..." from the context menu, enter some values, OK the dialog -- no change in the source (checked in text mode, hover text, and parameters view).
No tags attached.
Issue History
2009-12-22 00:32andrasNew Issue
2010-01-04 10:41levyAssigned To => levy
2010-01-04 16:20levyNote Added: 0000200
2010-01-04 16:20levyStatusnew => resolved
2010-01-04 16:20levyResolutionopen => fixed

Notes
(0000200)
levy   
2010-01-04 16:20   
ConnectionElement does not have a parameters child on its own,
there is an extra ChannelSpec level in between. Added a kludge
to ParametersDialog that fixes this issue and a TODO to eliminate
ChannelSpec.

X-Committed-on-Branch: maintenance