0000086: experiment/measurement/replication documentation out of date
The documentation [1] states that one can assign labels to experiment/measurement/replications in order to achieve a better graphical display of the recorded data.

I tried to add

 experiment = "attack.ini"
 measurement = "100-df63ff2da8aec31fa250df9b98aec7df"
 replication = "0-c0.4827876044234144c"

either into the "General" section or into a newly created "Config default"
section but omnetpp complained about
 <!> Error during startup: Unknown configuration key: experiment.
 OMNeT++ Discrete Event Simulation (C) 1992-2008 Andras Varga, OpenSim Ltd.
 Version: 4.0, build: 090310-10709, edition: Academic Public License -- NOT FOR
 COMMERCIAL USE
 See the license for distribution terms and warranty disclaimer
.

After digging in the source [2] I found these options be to appended
by "-label". This is not given in the manual but worked once the options were
changed into

 experiment-label = "attack.ini"
 measurement-label = "100-df63ff2da8aec31fa250df9b98aec7df"
 replication-label = "0-c0.4827876044234144c"

Sincerely,
 AZ

[1] http://omnetpp.org/doc/omnetpp40/manual/usman.html#sec293 [^]
[2] envir/sectionbasedconfig.cc:46-48
No tags attached.
Issue History
2009-07-19 18:43AZNew Issue
2010-04-25 19:27andrasNote Added: 0000248
2010-04-25 19:27andrasStatusnew => resolved
2010-04-25 19:27andrasFixed in Version => 4.1
2010-04-25 19:27andrasResolutionopen => fixed
2010-04-25 19:27andrasAssigned To => andras

Notes
(0000248)
andras   
2010-04-25 19:27   
Added missing "-label" suffixes.