OMNeT++/OMNEST Bug Tracker

View Issue Details Jump to Notes ] Issue History ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0000245OMNeT++runtime / Tkenvpublic2011-01-27 11:552011-01-27 11:57
Reporterrhornig 
Assigned Torhornig 
PrioritynormalSeverityminorReproducibilityalways
StatusresolvedResolutionfixed 
PlatformOSOS Version
Product Version4.1 
Target VersionFixed in Version4.2b1 
Summary0000245: Tkenv fails to display the graphical inspector if a syntax error is found in ini file
DescriptionIf one of the ini file parameters has a syntax error, tkenv fails to display the module that uses that parameter and exits with "Cannot access display string yet: parameters not yet set up" error. It rather should do a best effort to build up the network and use empty display strings if the parameters were not initialized for that module.
TagsNo tags attached.
Attached Files

- Relationships

-  Notes
(0000374)
rhornig (administrator)
2011-01-27 11:57

Code in tkenv now checks if paramateters are correctly initialized before trying to access the displayString.

- Issue History
Date Modified Username Field Change
2011-01-27 11:55 rhornig New Issue
2011-01-27 11:57 rhornig Note Added: 0000374
2011-01-27 11:57 rhornig Status new => resolved
2011-01-27 11:57 rhornig Fixed in Version => 4.2b1
2011-01-27 11:57 rhornig Resolution open => fixed
2011-01-27 11:57 rhornig Assigned To => rhornig