OMNeT++/OMNEST Bug Tracker

View Issue Details Jump to Notes ] Issue History ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0000660OMNeT++IDE / C++ developmentpublic2013-06-17 15:422013-06-17 16:03
Reporterandras 
Assigned To 
PrioritynormalSeverityminorReproducibilityhave not tried
StatusnewResolutionopen 
PlatformOSOS Version
Product Version4.3 
Target VersionFixed in Version 
Summary0000660: project not re-linked when new module is added to referenced project project
DescriptionCreate two projects:
  1. base: produces a static lib
  2. derived: references 'base', links with its static lib

Then create a new simple module in the 'base' project, then hit Build. The 'derived' project should be re-linked as a result, but it is not

Reported by Andras Ferencz.

TagsNo tags attached.
Attached Filestgz file icon a.tgz [^] (7,404 bytes) 2013-06-17 15:55

- Relationships

-  Notes
(0000803)
andras (administrator)
2013-06-17 16:03

See attached project. Build and run: there will be an error because of missing Sink class. Then:

$ mv Sink.cc.X Sink.cc <--- restores the Sink class so everything should be OK

Hit build again and run. It will STILL fail, because derived project is not re-linked.

Hit Clean All+Rebuild. It will now run.

Cause: missing dependency: target of link step should depend on the libs exported from referenced projects.

- Issue History
Date Modified Username Field Change
2013-06-17 15:42 andras New Issue
2013-06-17 15:55 andras File Added: a.tgz
2013-06-17 16:03 andras Note Added: 0000803


Copyright © 2000 - 2019 MantisBT Team