OMNeT++/OMNEST Bug Tracker

View Issue Details Jump to Notes ] Issue History ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0000717OMNeT++IDE / sequence chartpublic2014-02-10 15:372014-02-24 11:09
Reporterrhornig 
Assigned Tolevy 
PrioritynormalSeverityminorReproducibilityhave not tried
StatusresolvedResolutionfixed 
PlatformOSOS Version
Product Version4.4 
Target VersionFixed in Version4.4.1 
Summary0000717: Event log event filter problems
Description- After doing a filter and the pressing the button again nothing happens. A second click will invoke the dialog correctly. This happens each time the dialog opened.

- The tine limiting is not filtering correctly. Specifying a limit of 0.01 to 0.06 returns events with 0.073xxxx timestamps.
TagsNo tags attached.
Attached Files

- Relationships

-  Notes
(0000904)
levy (developer)
2014-02-24 11:09

Fixed the simulation time filter issue by replacing a call to getFirstEventNotBeforeSimulationTime with getLastEventNotAfterSimulationTime.

The other part of the bug report is not a bug. The way the filter button works when it is pressed instead of selecting from the drop down list is that it toggles between filtered and unfiltered eventlog.

- Issue History
Date Modified Username Field Change
2014-02-10 15:37 rhornig New Issue
2014-02-24 11:05 levy Assigned To => levy
2014-02-24 11:09 levy Note Added: 0000904
2014-02-24 11:09 levy Status new => resolved
2014-02-24 11:09 levy Fixed in Version => 4.4.1
2014-02-24 11:09 levy Resolution open => fixed