0000982OMNeT++simulation kernelpublic2017-01-11 15:222017-03-02 13:01
Reportertill 
Assigned Toandras 
PrioritynormalSeveritymajorReproducibilityalways
StatusresolvedResolutionno change required 
Platformx86-64OSmacOSOS Version10.12
Product Version 
Target VersionFixed in Version5.1 
Summary0000982: ${resultdir} variable gone or inaccessible?
DescriptionI cannot access the resultdir variable anymore. Was it removed?

Error in the ini with my custom vectormanager:
Could not read option checkoutputvectormanager-reportfile= from the configuration: No such variable: ${resultdir}
TagsNo tags attached.
Attached Files

- Relationships

-  Notes
(0001282)
rhornig (administrator)
2017-02-01 14:21

It should be still available. How do you read the configuration option in the custom vector manager?
(0001288)
till (reporter)
2017-02-01 14:46
edited on: 2017-02-01 17:41

I register the option like this:
Register_PerRunConfigOption(CFGID_CHECKOUTPUTVECTORMANAGER_REPORTFILE, "checkoutputvectormanager-reportfile",
        CFG_FILENAME, "${resultdir}/${configname}-${runnumber}-constraintReport.csv", "TBD");

and use it like this:
reportFilename = omnetpp::getEnvir()->getConfig()->getAsFilename(CFGID_CHECKOUTPUTVECTORMANAGER_REPORTFILE);

Until 5.0 this works. Problem occurs with preview 2:

<!> Error: Could not read option checkoutputvectormanager-reportfile= from the configuration: No such variable: ${resultdir}

(0001292)
till (reporter)
2017-02-01 15:15
edited on: 2017-02-01 17:59

Hmmm, Is it a problem to read the config in the constructor of the result manager?

It looks like the variables are not initialized then. But it must have something todo with changes for 5.1!

(0001308)
andras (administrator)
2017-02-03 14:25

It's not a good idea to read the option in the constructor. It is a per-run option, but the object is is created only once (and reused for all runs). When read in the constructor, different settings for each run will not take effect.

It is better to read the option e.g. in the startRun() method.
(0001309)
till (reporter)
2017-02-03 14:51
edited on: 2017-02-03 14:51

Understood!

What would be the correct place for an EventLogManager? startRecording()?

(0001310)
andras (administrator)
2017-02-07 10:34

The built-in eventlog manager EventlogFileManager (envir/eventlogfilemgr.cc/h) does such things in configure(), called from the LF_PRE_NETWORK_SETUP lifecycle event.
(0001331)
andras (administrator)
2017-03-02 13:01

Seems like it's been clarified... (Please reopen if not)

- Issue History
Date Modified Username Field Change
2017-01-11 15:22 till New Issue
2017-02-01 14:21 rhornig Note Added: 0001282
2017-02-01 14:21 rhornig Assigned To => rhornig
2017-02-01 14:21 rhornig Status new => feedback
2017-02-01 14:46 till Note Added: 0001288
2017-02-01 14:46 till Status feedback => @50@
2017-02-01 15:15 till Note Added: 0001292
2017-02-01 15:20 till Note Added: 0001294
2017-02-01 17:40 till Note Deleted: 0001294
2017-02-01 17:41 till Note Edited: 0001288 View Revisions
2017-02-01 17:59 till Note Edited: 0001292 View Revisions
2017-02-03 14:16 andras Assigned To rhornig => andras
2017-02-03 14:16 andras Status @50@ => feedback
2017-02-03 14:25 andras Note Added: 0001308
2017-02-03 14:51 till Note Added: 0001309
2017-02-03 14:51 till Status feedback => @50@
2017-02-03 14:51 till Note Edited: 0001309 View Revisions
2017-02-05 10:35 rhornig Status @50@ => feedback
2017-02-07 10:34 andras Note Added: 0001310
2017-03-02 13:01 andras Note Added: 0001331
2017-03-02 13:01 andras Status feedback => resolved
2017-03-02 13:01 andras Fixed in Version => 5.1
2017-03-02 13:01 andras Resolution open => no change required


Copyright © 2000 - 2017 MantisBT Team